Product List

Biogas Generator Set

Models
AMC30GF-PZ
AMC50GF-PZ
AMC90GF-PZ
AMC120GF-PZ
AMC140GF-PZ
AMC160GF-PZ
AMC200GF-PZ
AMC300GF-PZ
Engine model
NQ100N
Cummins 6B
Cummins 6BT
WT615
WT615.93
WT615.94
T12
BF8M1015
Conversion efficiency %
34.2
36.1
36.1
36.6
37.1
37.1
37.1
39
Engine type
4 stroke、naturally aspirated
4 stroke、turbocharging
Engine capacity
3.759
5.9
5.9
9.726
9.726
9.726
11.596
15.876
Rated speed (rpm)
1500
1500
1500
1500
1500
1500
1500
1500
Engine type
FD2C1-4
ECO32-3L/4
ECP34-1L/4
ECP34-2L/4
ECO38-1SN/4
ECO38-2SN/4
ECO38-1LN/4
ECO40-1S/4
Engine conversion efficiency %
87.5
90.8
92.4
92.8
93
93.1
93.4
93.9
Rated Voltage (V)
230/400
230/400
230/400
230/400
230/400
230/400
230/400
230/400
Rated Frequency (Hz)
50
Power factor
0.8(hysteretic)
Continuous output
kW
27
45
81
108
126
144
180
270
kVA
33.75
56.25
101.25
135
157.5
180
225
337.5
A
48.7
81.2
146.1
194.8
227.3
259.8
324.7
487.1
Rated Output
kW
30
50
90
120
140
160
200
300
kVA
37.5
62.5
112.5
150
175
200
250
375
A
54.1
90.2
162.4
216.5
252.6
288.6
360.8
541.2
Starting mode
24VDC electrical starting
Speed regulation mode
Electronic speed governing
Fuel control mode
Lean burn,closed-loop control
Lean burn,closed-loop control
Sparking mode
Electronically controlled single cylinder independent high-energy ignition
Operation mode
One key start and stop
Voltage adjustment rate
≤±3%
≤±3%
≤±2.5%
≤±2.5%
≤±2.5%
≤±2.5%
≤±2%
≤±2%
Floating voltage waveform deviation factor
≤8%
≤8%
≤6%
≤5%
≤5%
≤5%
≤3%
≤3%
Exciting mode
Brushless excitation (AVR control)
Voltage adjustment rate
- 20 % ~ + 25 %
- 20 % ~ + 25 %
- 20 % ~ + 25 %
- 20 % ~ + 25 %
- 20 % ~ + 25 %
- 20 % ~ + 25 %
- 10% + 15 %
- 10% + 15 %
Voltage recovery time (S)
≤5
≤5
≤4
≤3
≤3
≤3
≤1.5
≤1.5
Insulation grade
H
H
H
H
H
H
F
F
Level of protection
IP21
IP21
IP21
IP21
IP21
IP21
IP21
IP22
Gas consumption rate kW·h/Nm³
1.79
1.96
1.99
2.03
2.06
2.06
2.07
2.19
Fuel value MJ/Nm³ (60% methane)
21.53
21.53
21.53
21.53
21.53
21.53
21.53
21.53
Fuel value MJ/Nm³ (60% methane)
16.8
25.5
45.1
59.1
67.9
77.6
96.6
137.0
Weight kg
780
1000
1200
1450
1750
1850
1950
3350
Dimension (mm)
1720×820×1250
2170×900×1400
2240×1000×1400
2700×1120×1600
2900×1150×1680
2900×1150×1680
3200×1150×1720
3200×1400×1800

Prime Power Gas Generator

  • Dealer and distributor of industrial gas, diesel, multi-fuel engines, standby generators, prime power generators, rentals and parts.
  • Prime and standby power generation sales, parts and service.
  • Engineering consultant specializing in gas and steam turbines and generators.
  • Light Fuel Gas Generator Set

  • Providing reciprocating generator sets and co-generation systems with diesel engines, natural gas engines, and heavy fuel oil engines.
  • Specializes in cleaning contaminated fuels and light oils.
  • Supplies advanced fuel filtration water separation devices, fuel polishing systems and associated components to the generator, agriculture, earth moving, crane, transport and marine markets.
  • 2000kW Gas Engine Genset

  • Manufacturer of electric generators, diesel and natural gas driven, from 4 to 2000kw.
  • Supplies Caterpillar diesel engines, gensets, marine propulsion, industrial engines.
  • Manufacturers of industrial diesel engines, propulsion engines and Gensets. List of all engine types made since 1895.
  • 1200kW Gas Engine Genset

  • Supplies Caterpillar diesel engines, gensets, marine propulsion, industrial engines.
  • Manufacturers of industrial diesel engines, propulsion engines and Gensets. List of all engine types made since 1895.
  • Manufacturers of industrial diesel engines, propulsion engines and Gensets. List of all engine types made since 1895.
  • Biogas Generator Set